HT Series Machine Operation Process
1 Before power on, please check switches of the panel and see that whether knob 8 is position or not. Of there are voltage-limiting/current-limiting adjustable knob, it should be in the max. position.
2 After powe source switch 13 turned on, protection indicator 5 will flash for a few seconds and then turn off. At this time, power source is at delay standby state. After that, turn startup switch 10 from "off" to "on", power source can then run normally.
3 Directions for use of time control function:
4 Before power on, place time control switch at "time control off" and pause 11 at "working" position, startup switch 10 at "shut", current regulating/voltage regulating switch 9 at proper position. output adjusting knob 8 at min. position.
5 Switch on, turn startup switch 10 at "start" position. The power sources begins to work. And adjust knob 8 to proper output voltage (current) valve.
6 When needing time control, please set time relay 1 and then place "time control switch" at "time control on". Then, time relay 1 begins to count.
7 In course of timing, if pause needed, you can turn working switch 11 from "working" to "pause". Displayed value will be kept. When pause restored to "working", timing continues. To return to zero at any time, you can turn "working" switch from "working" to "restoration" position.Then timing will return to zero. And time relay begins to keep time from zero when the switch back to "working".
8 Directions for Use of Time Relay
Time Relay Range (weighted code of period of use time to be set) |
Hour(H) |
1 minute-99 hours 99 minutes |
Minute(M) |
1 second-99 minutes 99 seconds |
Second(S) |
0.01 second-99.99 seconds |
9 Directions of Remote Control
10 Operation indicators of remote control box are same as those of above ordinary panel operations. |
|