Controllable Silicon Rectifier vs High-frequency Switch Power Supply
|
Take 500A/12v for exampl
|
Comparing Parameter
|
Controllable Silicon Rectifie
|
High-frequency Switch Power Supply |
Transformer |
with linefrequency transformer,
ultra large size,
with weight of 60kg
|
no linefrequency transformer, with high-frequency transformer, weighing 1.5kg |
Controlled Parts |
Controlled SCR |
IGBT |
Working Frequency |
50HZ |
20KHZ或250KHZ |
Control Mode |
Phase-shifting Triggering |
PWM Modulation |
Output Filtering |
No |
Yes, with apparent effect |
Output Uniflow |
Half-wave |
Uniflow square wave of high density |
稳压精度 |
<5% |
<1%,甚至可达<1% |
稳流精度 |
<5% |
<1% |
冷却方式 |
水冷/油冷/风冷 |
风冷 |
效率 |
70%左右 |
90% |
功率因素 |
0-0.9可变 |
全范围可达0.9以上 |
控制电路 |
复杂,有同步要求,不易集成 |
简单采用专用集成板电路,并做过防腐处理,完全密封 |
体积及整机重量 |
体积大,500A/12V设备体积 530(长)*500(宽)*1030(高)。整机重量120kg. |
体积小,500A/12V设备体积
520(长)*390(宽)*520(高)。520(长)X300(宽)X220(高)
整机重量17.5kg 。 |
带载启停 |
不允许 |
允许 |
输入电压允许波动范围 |
±10% |
±15% |
对电网干扰 |
大,且不易消除 |
很小,易消 |
调节影响速度 |
一般 |
极快 |
节能效率 |
差 |
节能明显,与普通可控硅比可节省电30% |
机自动控制程度 |
一般 |
智能 |
1. Before power on, please check board or remote control cabinet switches to see whether there or flexible or damaged ones. The switch of “working” “standby”should be at “standby”mode.
2. Turn on air switch of rear cabinet of the machine, failure indicator will flash for a few seconds and then turn off. At this time, the machine is at standby state. When “working”“standby”switch is at “working”mode, the machine begins to work and there are voltage ouput. When inputting 380V three-phase power, the machine and failure indicator will flash if there are phase loss, over voltage or voltage shortage. And same case if there isn't any voltage and current output at all, or blocked machine ventilation.
3. For time control device, if the preset time is due, there would be music alarm, without output voltage and current. After manual or automatic restoration, the machine then runs normally. If plated matters are in bad contact, it also will give warnings and timing pauses automatically.
4. All buttons on selection box have same functions as those of knobs on the panel.
5. Blower fan of the machine blows outward. To blow inward, you can exchange any two phases of the three-phase wires. |
|